Mass Spectrometers
Atmospheric-Pressure MALDI
The Atmospheric-Pressure Matrix-Assisted Laser-Desorption Ionisation (AP-MALDI) source enables mass spectrometers fitted with an electrospray
or nanospray source to have the additional capability of MALDI. It is called
AP-MALDI because, unlike vacuum MALDI, ionisation takes place under
atmospheric conditions. This provides several important advantages including
convenience, speed of analysis, simplicity of operation and cost.
New for 2007! - Existing AP-MALDI users can now upgrade
existing nitrogen lasers to the new Nd-YAG laser
-see below for more details
Features
|
 |
Change between MALDI and ESI/nanospray in minutes. Calibrate in ESI and switch
to MALDI without recalibration. Sample plates loaded in seconds as there is no waiting
for vacuum to be achieved.
|
 |
MS-MS and MSn data (If instrumental capabilities permit) from a MALDI source for enhanced sequencing information
at a fraction of the cost of a TOFTOF instrument.
|
 |
Superior performance, simpler operation and more reliable MS-MS capability than MALDI-TOF post-source decay (PSD)
|
 |
Robotic control of MALDI targets with CCTV point-and-click visual alignment checking for
confidence in operation
|
 |
Windows control software interfaces seamlessly with existing control and acquisition software
provided by instrument manufacturer to make operation simple.
|
 |
Versions available for Thermo-Finnigan Classic, Duo, Deca, Deca XP Deca XP Advantage and LTQ linear
trap LTQ-FTMS and Orbitrap; Bruker
ion-traps and FTMS, Waters/Micromass Q-TOF and LCT, ABI QTraps, Shimadzu QIT and the Varian 500 LC-MS ion trap.
|
The MassTech AP-MALDI source as fitted to a Thermo-Finnigan LTQ-FTMS.
AP-MALDI data at 200,000 RP of BSA digest from a Thermo LTQ-FTMS.
Click here for larger image
New Nd-YAG Laser
The third-generation versions of the AP-MALDI source are fitted with the new all solid-state Nd-YAG laser.
This has several
advantages over the nitrogen laser versions.
Features
|
 | Integrated
pulsed-dynamic-focussing (PDF) for maximum sensitivity
|
 |
All solid-state Nd-YAG laser guaranteed for 1 billion firings for increased
reliability and low cost-of-ownership
|
 | Up
to 200 Hz repetition rate for higher throughput and faster imaging
|
 |
Software-controlled attenuation for more reproducible analyses
|
New Software and Sample Capabilities
The latest version of the Target software includes many enhancements.
Features
|
 |
New raster pattern motion with precise control of stage speed for MALDI imaging
|
 | Automated
recognition of target spot centres to complement automatic
sample-spotting devices
|
 |
New sample plate holders including dense 384-spot plates, ABI Opti-TOF 192-spot
plates and Waters DIOS plates
|
For further details on any of these products contact KR Analytical.
|